ECM-V

Submersible drainage pumps with plunged back impeller Vortex type. Suitable in civil and industrial water systems, for cesspool drainage with slighlty dirty or foamy liquids, for oily waters cleaned by grid.

DOWNLOAD DATA SHEETDownload the manual
Limits of use:
- Liquid temperature up to 35°C
(for home use according to EN 60335-2-41)
- Temperature max. liquid: 35°C (for other uses)
- Maximum immersion depth 20 mt.
(with a cable of the appropriate length)
- Grain size inlet Ø 30 mm
- Min. suction level 100 mm
- Continuous duty
Engine:
- Single-phase 230V-50Hz
- Three-phase 400V-50Hz - Insulation Class F - Protection IP 68


- Thermic protection (only single-phase)
Material:
- Motor body: Cast Iron
- Pump body: Cast Iron
- Impeller: Cast Iron
- Shaft with rotor: Stainless Steel AISI 304
- Mechanical seal with oil chamber Silicon/Silicon/NBR
MODEL PHASE NOMINAL POWER POWER CONSUMPTION PERFORMANCE SHOUTS
HP kW kW Q (L/min) H (m) asp. mand.
ECM 75 VS Single-phase 0.75 0.55 0.9 300 8.5 2″
ECM 100 VS Single-phase 1 0.75 1.1 350 9.5 2″
ECT 100 V Three-phase 1 0.75 1.1 350 9.5 2″
Weight 1.0000 kg
Applications

Residential Civil Home

Manuale

Type of fluid

Dirty water

Famiglia

ECM-V

Prevalenza Massima (m)

9.5

Portata Massima (L/min)

350